    Our Composite ACM Rain Screen System is an Aluminum Composite metal wall and fascia panel system for buildings, aluminum composite walls, metal soffit, and metal storefronts..

    Our CAP Series "RS" Rain Screen panel system is a drained and back ventilated rain screen incorporating a strip of composite material in the reveal between each panel (instead of caulk) resulting in a more uniform appearance. The rain screen Series "RS" comes with fabricated panels and shipped-loose “track” extrusions. The fabricated panels include a “frame” extrusion, factory attached to the routed and returned edges of the panel that fits conveniently into the field installed horizontal and vertical “track” extrusions. CAP’s Series "RS" rain screen is designed to allow moisture to permeate the outside wall, but subsequently drain through weep holes along the bottom edge of each panel. While any remaining moisture is designed to evaporate, the outside wall is not designed to act as a water/vapor barrier for the building.

    Product Number Equivalents:
    Firestone Una-Clad Series 1200, Series 1500. Also Firestone Una-Clad Series 2500, 3000UC, 3200, 4000, & 4500 are equal to our CAP ACM Rain Screen

    Specifications

    Aluminum Composite Wall Panels (Rain Screen) Specifications Section 07 42 43 Composite Wall Panels


    PART 1 - GENERAL

    • 1.01 Summary

      1. An aluminum composite panel used as the exterior/interior cladding of new buildings and retrofit applications.

    • 1.02 Related Sections

      A. 05 10 00 Structural Metal Framing
      B. 05 40 00 Metal Framing
      C. 07 20 00 Thermal Protection
      D. 07 60 00 Flashing and Sheet Metal
      E. 07 90 00 Joint Protection

    • 1.03 Submittals

      A. Shop drawings shall show panel system including proprietary extrusions, attachment methods, joinery, non-exposed sealants/gaskets, size/type and location of all fasteners including rivets and stiffeners.

      B. Finish samples shall be minimum 3.5” x 3.5” of aluminum composite material in the specified panel finish.

      C. Material samples shall be minimum 12” square with perimeter extrusions in place, not necessarily in the specified panel finish.

      D. Three copies of the manufacturers and fabricators literature.

    • 1.04 Quality Assurance

      A. Composite panel manufacture shall have a minimum of 15 years’ architectural experience in the manufacture of this product and be located within the continental United States.

      B. Installer shall be approved by the fabricator. Supporting documentation shall be forwarded to the Architect.

      C. Maximum deviation from the vertical and horizontal alignment of erected panels shall be not more than 1/4” in 20’-0”.

      D. Painted surfaces of the aluminum composite panels shall meet the criteria printed in the manufacturer’s printed literature.

      E. Where possible and without delaying project, field dimensions are to be taken by the installer prior to commencement of fabrication.

      F. Coordinate fabrication schedule with construction progress as directed by the contractor to avoid delay of work.

    • 1.05 Product Delivery, Handling & Storage

      A. Protect panel finish and edges per panel manufacturer’s recommendations.

      B. Store material in accordance with manufacturer’s recommendations, on skids & tarped.

      C. Contractor to provide adequate space for storage for each panel elevation.



    PART 2 - PRODUCTS

    • 2.01 Specified Manufacturer

      A. General
      1. Columbia Architectural Products Inc., dba Metal Panel Store, Series "RS" composite wall panel assembly. 10722 Tucker Street, Beltsville, Maryland 20705 301-937-4383 www.metalpanelstore.com
      B. Panels shall be 4mm PE core aluminum composite material, Larson, as manufactured by Alucoil North America or equal.

    • 2.02 References

      A. American Society for Testing and Materials
      1. E330: Structural Performance of Exterior Windows, Curtain Walls and Doors under theinfluence of Wind Loads.
      2. E283: Rate of Leakage Through Exterior Windows, Curtain Walls and Doors.
      3. D1781: Climbing Drum Peel Test for Adhesive Materials.
      4. E84: Surface-Burning Characteristics of Building Materials.


      C. Composite panels shall have PE Core and a Class “A” building material rating when tested in accordance with ASTM E84 (Steiner Tunnel Test) and shall exhibit a flame spread of 15 and a smoke developed rating of 120, with a center panel joint.

      D. Panels shall have passed the ASTM E108 modified test.

      E. Panel thickness - RB160 (4mm),

      F. Panel weight - RB160 (4mm) = 1.2 lbs/sq.ft.

      G. Panel Finishes:

      1 Coating shall be a fluoropolymer coating utilizing 70% Kynar 500 resins.

      a. Color as selected by owner/architect from manufacturer’s standard colors.
      b. Coating shall be factory applied 2 coat process, continuous paint line. Coatingshall consist of a 0.2 mil prime coat, a 0.8 mil color coat containing 70% Kynar resins, and a 0.5 mil clear coat containing 70% Kynar resins if a metallic coat is required.

      2. Pencil Hardness – ASTM D3352Shall be HB-H minimum (Eagle Turquoise).

      3. Reverse Impact Adhesion – ASTM D2794Coating shall show no cracking and no loss of adhesion

      4. Abrasion Resistance-Falling Sand – ASTM D968Coating shall withstand 50+ Liters.

      5. Humidity Resistance – ASTM D2247Coating shall show no blisters after 3000 hours of 100% humidity at 95`F.

      6. Salt Spray Resistance – ASTM B117-85After 3000 hours of exposure. Atlas Weather-Ometer Test – ASTM D822Coating shall show no cracking, peeling, blistering or loss of adhesion after 2000 hours.Aluminum Composite

      a. Chalk Resistance – ASTM D4214Variability up to +/- 0.8 delta
      b. Color Retention – ASTM D2244Variability up to +/- 0.5 delta
      c. After 5000 hours in Atlas Weather-Ometer coating shall show no objectionablechalking or color change.

    • 2.02 PANEL FABRICATION
      A. Composition

      1. Aluminum composite material shall be composed of a thermoplastic core sandwiched between two aluminum sheets formed in a continuous process with no applied glues or adhesives.

      2. Bond integrity per ASTM D1781-76 and ASTM C481 Cycle B, shall be a minimum of40 in-lb.in. (Peel Strength)

      B. Aluminum face sheets

      1. Thickness .020” of 3105 H25 aluminum alloy.

      C. Tolerances

      1. Panel bow shall not exceed 3.8% of panel overall dimension in width or length.

      2. Panel dimensions shall be such that there will be an allowance for field adjustment and thermal movement.

      3. Panel lines, breaks and curves shall be sharp, smooth and free from warps or buckles.

      D. Panel surfaces shall be free of scratches or marks caused during fabrication.

      E. Ensure that entire project is manufactured from single color coil paint run to ensure color uniformity.

      F. If a metallic color is selected ensure that panel grain is maintained. Under no circumstances are panel blank sizes to be rotated even if material waste in increased.

    • 2.03 ACCESSORIES

      A. All exposed fasteners shall be chemically coated or stainless steel.

      B. All hidden fasteners shall be chemically coated or stainless steel.

      C. System is to be Dry Seal / Rain Screen principal with an aluminum extrusion frame and no exposed fasteners.

      D. Rod and sealant shall be used only at points where panels meet dissimilar materials.



    PART 3 - EXECUTION

    • 3.01 Inspection

      A. Panel substructure shall be level and plumb.

      B. Panel substructure shall be free of defects detrimental to work and installed in accordance with established building tolerances.

    • 3.02 INSTALLATION

      A. Install panels level and plumb, in proper alignment in relation to substructure framing and established lines.

      B. Panels shall be erected in accordance with approved shop drawings.

      C. Where aluminum materials come in contact with dissimilar materials, an isolation shim or tape shall be installed at fastening locations.



    PART 4 – MATERIAL VARIATIONS

    • 1.01 Submission Format

      A. Alternate materials will only be considered if applied for in writing to the Architect 10 days prior to bid date.

    • END OF SECTION

    Tech Data

    Product Name:

    Series "RS" Rain Screen ACM Panel System

    Manufacture

    Columbia Architectural Products, Inc.
    10722 Tucker Street
    Beltsville, Maryland 20705
    phone: (301) 937-4383
    fax: (301) 937-6850
    web: www.metalpanelstore.com

    Panel Description:

    The CAP Series "RS" Rain Screen panel system is a drained and back ventilated rain screen incorporating a strip of composite material in the reveal between each panel (instead of caulk) resulting in a more uniform appearance.

    Our CAP Series "RS" Rain Screen composite panel system is a drained and back ventilated rain screen incorporating a strip of composite material in the reveal between each panel (instead of caulk) resulting in a more uniform appearance. The rain screen Series "RS" comes with fabricated panels and shipped-loose “track” extrusions. The fabricated panels include a “frame” extrusion, factory attached to the routed and returned edges of the panel that fits conveniently into the field installed horizontal and vertical “track” extrusions. CAP’s Series "RS" rain screen is designed to allow moisture to permeate the outside wall, but subsequently drain through weep holes along the bottom edge of each panel. While any remaining moisture is designed to evaporate, the outside wall is not designed to act as a water/vapor barrier for the building.

    ACM Panel  Rain Screen Panel

    30 Year Architectural Coatings

    Larson by Alucoil ACM is coil coated utilizing Duranar coatings from PPG. Backed by a 30-year exterior performance warranty., these (PVdf) fluorpolymer paint finishes contain 70% Kynar 500/Hylar 5000 resins and are formulated to meet or exceed industry performance e requisites such as AAMA 620. Our 25 standard colors are matched to a combination of popular ACM and foam panel colors – enabling greater flexibility and design choice.

    Solid Color Series

    These Duranar 2-coat colors consist of a 0.2 mil primer and 0.8 mil color coat, for a nominal dry film thickness of 1.0 mil.

    All standard colors are stocked in 62” coil. Select colors are also available in 52” width. Inquire for details and finished panel inventory in key colors.

    Greater Flexibility in Custom Colors

    With a 1,000 square foot minimum for custom colors, Larson by Alucoil takes a different approach to address a growing trend in the market. Available in 62”, 50” and 39.37” widths, there are no hidden set up charges – just one price for the quantity required.

    Due to variations in computer monitors, we cannot guarantee the accuracy of colors presented on screen with actual products.

    Standard Colors ACM Composite Aluminum

    Standard Colors

    These Duranar 2-coat mica colors consist of a 0.2 mil primer and a 0.8 mil color coat, for a nominal dry film thickness of 1.0 mil. Mica flakes are suspended in the color coat – giving the appearance of a metallic finish.

    Standard Colors ACM Composite Aluminum

    Mica Color Series

    These Duranar 2-coat mica colors consist of a 0.2 mil primer and a 0.8 mil color coat, for a nominal dry film thickness of 1.0 mil. Mica flakes are suspended in the color coat – giving the appearance of a metallic finish.

    ACM Composite PPG Mica Colors

    Metallic Color XL Series

    These Duranar 3-coat metallic colors consist of a 0.2 mil primer, a 0.8 mil color coat, and a 0.5 mil clear coat, for a nominal dry film thickness of 1.5 mils.

    Metallic Color XL ACM Composite Aluminum Colors

    Mica and Metallic XL Colors are directional in nature therefore proper estimating and installation precautions should be taken to ensure that panels are all installed in the same direction. Directional arrows are painted on protective vinyl film to aid in this practice.

    Due to the reflectivity of these finishes, optical perception of color tone may vary according to the angle from which the panels are viewed, reflected light off at other structures, and different angle planes on which the panels are installed on a building elevation.

    To ensure color consistency with these finishes, it is recommended to order all material required at the same time, be they in single or multiple widths.

    PPG Coatings Protected

    Drawings

    Aluminum Composite Panel- Rain Screen System
    4mm Alucoil ACM Fabricated by Columbia Architectural Products in our Factory
    Aluminum Panel Composite Rain Screen System
    Aluminum Composite Material Rain Screen Panel Details 4mm Alucoil ACM
    Aluminum Composite Material Panel - Rain Screen System
    .